Below: the Fleck brand water softener bypass valve set to SERVICE, meaning that the softener is "in use". Make sure the drain line flow remains steady for 10 minutes or until the water runs clear. For those wondering, Should I manually regenerate my water softener? The answer is probably yes. The water softener shown above, installed in a Surprise Arizona home, was placed by Pro-Tec Water Softeners (Pro-TecWater.com). When the water softener is on "bypass" water used in the building is not passing through the water softener - the unit will not be treating the building water supply.Bypassing the water softener and turning it off when the building water supply is not going to be in use removes one more possible source of freeze and or leak damage and it also isolates the water softener equipment from the rest of the building water supply piping. Below: we show the Fleck water softener bypass control valve set to BY PASS or "out of service". Water Softener Bypass Valve Operation & Repair Guide: This article explains how to use & repair the water softener or water conditioner system bypass valve. Set time of day, program wheel, and salt usage. in my earlier question I said there was about 3/4 inch more in the liquid level of the brine tank after the brine draw finished? Doing this should remove the iron and soften your water again. This code comes up when that doesnt happen. Flow Meter Type (FM): Set this to T0.7. How maddening I just posted a long comment with suggestions and the darned "comments box" code snarled up and lost it all. Watch out:do not leave off the water softener indefinitely. You will see about an inch of the bypass pipe stick out the opposite side of the handle. Watch out: Remember that if an additional external manual bypass valve is "open" (on bypass or in bypass) you will need to also close that valve when the water softener is returned to service ("off bypass"). The Package Length of the product is 1.78 inches. The tiny green arrow showing in the window pointed-to by the white arrow shows that this unit is in operation. Some problems with the unit are as a result of the softener not being programmed correctly. Then remove the back cover, the housing screws and the screw in the center of the main piston. This will allow for enough water to be added to the tank before shutting the brine fill cycle. After 60 minutes of being in this cycle 2 (brining cycle), it will move to cycle 3, which is a 6-minute second backwash cycle. Unplug the unit, assess all components for damage, and make replacements if needed to fix this. Remove the brine tank tubing where it enters the units control valve. How to Fix a Leaky or "Stuck" Water Softener Bypass Valve In our experience these manual bypass valves work pretty well on most water softeners, but on occasion we find one that is leaking. When I was building out the copper piping from the bypass valve the male adapters turned a bit and even though they were returned to the original position not surprisingly they leak at the threads. I did not see an answer as to whether fresh water is being used during the brine draw which causes pressure gauge to change? Apply silicone lubricant to four new O-rings and assemble to four ports on the new water module. 2) Gently remove the bypass valve from the connection. sigh Ive read numerous accounts where the my softener brand is suppose to basically remove most of the water in the brine tank by the end of the cycle, but of course not the case for me. What this means is that the household water is not flowing through the media tank and will not be softened. 1. Prevention and repairs on these two primary causes can save a fortune in other maintenance. the bypass valve shown in this sketch from a Culligan water softener installation manual includes replaceable o-rings that may be needed if your bypass valve is leaky. The injector screen could be plugged. Check the brine in the brine tank and make sure there is enough. The fleck bypass valve fits well with the filter system and it is black. Look for writing and arrows on the bypass valve control knobs. Your water softener needs attention if you see the Fleck 5600sxt flashing water drop. 2. 3 inches. Count to three after plugging the power cable in and then release the next cycle button. In some cases, it may need to be cleaned or replaced, if there is suction at the control valve but no brine is being drawn in. If you find any leaks, create a seal using an o-ring or other sealant. You may need to buy another bypass valve if you do not have a rebuilding kit. Then close tap. . After doing the above, then hold down the up and down arrow simultaneously for 5 seconds. Our Comment Box is provided by Countable Web Productions countable.ca, Click to Show or Hide Citations & References, Put the water conditioner in or out of service, .when unit is brining there is a slow trickle out the drain hose but the brine tank level does not drop, no soft water and it was because of the bad O rings on the Bipass valve, TURN WATER SOFTENER ON / OFF / OUT OF SERVICE, CULLIGAN PUSH TYPE BYPASS VALVE OPERATION, FLECK or PENTAIR WATER SOFTENER BYPASS VALVE, KENMORE (SEARS) WATER SOFTENER BYPASS VALVE, PROTEC WATER SOFTENER BYPASS VALVE OPERATION, PIPING ARRANGEMENT & LOCATION of MANUAL BYPASS VALVE, WATER QUALITY & QUANTITY San Miguel de Allende, KENMORE WATER SOFTENER with Ultra Flow Valve MANUAL, HOME INSPECTION EDUCATION COURSES (Canada), HOME INSPECTION EDUCATION: HOME STUDY COURSES, [4] North Dakota Standards for Water Softeners, North Dakota General Authority Law, Chapter 62-04-08, Water Softener Units http://www.legis.nd.gov/information/acdata/pdf/62-04-08.pdf. Installation Instructions for Water Softeners with Fleck 5600 and 5600SXT Covers standard water softeners using a separate brine tank. Remove two screws and clips at control valve. Press Extra Cycle button to go to the next step. But, like other equipment and appliances, these units can also have issues every now and then. Place the bypass in the In Service position and let water flow into the mineral tank. There are no kinks in that or any of the other tubing, been checked. Press or hold the Extra Cycle button for 5 seconds. use the bypass valve, Luke. Watch out: put the water softener in bypass mode only when repairs are needed. Keep reading to learn about some of the most common Fleck 5600 issues and troubleshooting tips. If you have your water tested and it has 0.5 mg/L (or ppm) or more of iron, then use the settings below: To modify the programming specific to your application, you first need to enter the programming mode by setting the time to 12.01 PM. Lubricate the distributor o-ring seal and tank o-ring seal. A faulty or clogged valve may also hinder the units functionality. Position the valve to backwash. So today I took the venturi apart again and cleaned it for the umpteenth time.I've replaced all gaskets on the head, gaskets in the venturi, cleaned the brine tube and probably a ton of things I can't remember Today I actually watched while in brine mode which I assume means the brine is being sucked thru the resin tank and they down the drain hose? You may need to repeat this step. All you need to do now is set the clock to the right time of day by holding the Up or Down arrow. Fleck 5600 O-ring After all it's opening cops or running Plumbing fixtures in the building that uses more or less water.The subtle exception might be that for some models of water softener if the unit is not operating correctly it might have been regenerated more frequently than necessary. Turn the manual regeneration knob slowly in a clockwise direction until the program micro switch lifts on top of the first set of pins. This code means the system failed to regenerate, so perform a manual regeneration to kickstart the system. at WATER SOFTENER ADJUSTMENT & CONTROLS, a water softener is not there just for fun. If it is sucking strongly, check the brine tank float inside the brine well and make sure there are no rubber bands around it, and that there are no obstructions. Turn on the water to the house and run the water in the house for a few minutes after the regeneration process is complete. Sometimes if the brine tank is not filling adequately, it may be as a result of the float assembly in the tank being set too low. If you are also installing a water softener, install the softener after the 2510 SXT Air Injection filter. if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[300,250],'icdsc_org-large-leaderboard-2','ezslot_11',146,'0','0'])};__ez_fad_position('div-gpt-ad-icdsc_org-large-leaderboard-2-0'); Remedying this situation generally requires some routine maintenance, such as cleaning the flow control, cleaning the injector screen, replacing the timer, replacing the brine valve seat, replacing the clean valve, or cleaning the brine line flow control. Recapping: Be sure you've checked for some embarrassing snafus like routing the drain hose too high or an obvious kink or leak in tubing anywhere; Then Let's go through the diagnostics in the manual, of which there are 2 sets, starting on p. 17 and including a factory reset. The soft water flows up the riser tube to your plumbing fixtures. A valve that was not programmed correctly using the Fleck 5600sxt installation manual will require you to check the timer program control positioning. This item: Fleck COMINHKR047408 FBA_60049 Replacement Bypass, 1 Count (Pack of 1), Black $35.99 Valumax Fleck 18706-02 3/4 Plastic Yoke Male NPT Bypass $14.99 1" Noryl Yoke fiber-reinforced polymer Replacement for Fleck Control Valve - Water Softener Accessories $13.31 Compare with similar items Product Description Still trying to fix this Whirlpool softener for the last 6 months! Other causes could be an internal control leak, low line pressure, or a malfunctioning service adaptor that wont cycle efficiently. I'm so sorry for all these messages I just want some closure. Plug the electrical cord into the outlet. "the level in the brine tank doesn't recede" - if you're talking about visible salt, that could be normal or there could be a salt bridge. This means it is set for standard Downflow mode. This valve also contains a seal. Otherwise, the meter may as well be faulty and needing to be replaced. What this means is that the household water is not flowing through the media tank and will not be softened. Then turn off water supply to the water softener. Get the bypass valve and 3/4" male connections. A water softener does not know if the water is running through it continuously. You should now be able to lift off the entire timer assembly. Water pressure automatically builds up in the softener. Make sure the unit is drawing water from the brine tank. Their products are also reliable, delivering all the benefits you seek from a water softener. Make sure that the floor is clean beneath the salt storage tank, and that it is level. Here is a comprehensive guide with common Fleck water softener issues that you can use: In the softener, water enters the top of the tank and flows down through the media and up the distributor tube. ..I pulled the hose from the drain tube while it was in brine mode, water seemed to be coming out fine, not rushing, but then again it's suppose to be a slow trickle so they say, a bit more than a trickle in my opinion though. Press the Extra Cycle button t accept the setting and move to the next parameter. Subtract the necessary reserve requirement and set the gallons available at the small white dot on program wheel gear. While holding this button down, plug the power cable back into the wall outlet. Mother EFFER! Make sure the by-pass valve is in the bypass position when starting . You can solve this by cleaning the injector, screen, and drain line flow control. To fix this, change the seals, spacers and/or the piston assembly. If your water softener has a manual bypass valve (photo at page top and sketch at left), you can temporarily take the water softener "out of operation" - that is, you can put the the valve into bypass position so the water softener is not in the piping loop at all. Make sure the clips legs are firmly engaged with lugs. Most water softener models using this "push-push" style of bypass valve include colored knobs on each end of the valve as well as text on the knob that indicates whether or not the valve is in "on" position or "bypass" position. This step-by-step video will show you what to do so that you can activate the bypass yourself and prevent water damage right away. If there is no suction at the control valve port where you have removed the brine line tubing, then you should clean the injector. Assemble meter to control valve. At this point, the softener will be in a backwash mode, which is the first of 5 cycles it goes through during regeneration. Some however use black knobs but mark them as ON (in = on) or OFF (in = off). Why is my water softener not regenerating automatically? To verify the backwash flow rate, run the drain line into a bucket and time it when the 5600-SXT is in cycle 1 (backwash). This seal fits both the brass and stainless steel bypass valves It fits both the 3/4 and 1 bypass valves This valve fits the 5600 series, 2510, 6600, 6700, 9000, 9100, and some other Fleck models. Follow the quick steps below for a softener reset:if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[300,250],'icdsc_org-leader-3','ezslot_17',151,'0','0'])};__ez_fad_position('div-gpt-ad-icdsc_org-leader-3-0'); 2. Rotate the cable to align drive flat if necessary. If necessary, set salt according to the setting instruction sheet. You can rotate the control knob just to be certain. Leak on Fleck Bypass Valve using PVC Fitting. Flush and clean the water supply from the washer. [Click to enlarge any image]. Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia. So I'm asking this old question againwhen unit is brining there is a slow trickle out the drain hose like it's suppose to. Return bypass or inlet valving to the normal In Service position. rush out the drain hose normally so I don't believe the drain is the problem. Have you tried starting over, factory reset, then following the diagnostic steps given in the manual as cited earlier?Have you actually measured the regen drain volume?Have you tested the water after regen to see if it's hard or soft?I'd arm myself with those steps before calling product support 1-866-986-3223 o, don't tell me you're leaving me already lol.. Manually index the control to the Backwash position and allow water to flow at the drain for 3-4 minutes. See that white arrow to the right of the valve handle (the handle is in a "vertical position)? There are various cutter sizes, depending on the space surrounding the pipes to be cut. WATER SOFTENER BYPASS VALVE at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice. The setting is optional and can be set to 0, but it can be useful if you have iron or other sediments to keep the softener clean. Be sure the injector is drawing in the brine: This is another common problem that occurs if you do not have enough backwash flow rate to clean the water softener properly. Press Extra Cycle button to go to the next step. Moving clockwise from red pointer, extend or retract fingers to obtain the generation schedule. It depends on the settings you choose and the size of the property, but a Fleck 5600 water softener regenerates every three to fifteen days. A wheel type tubing cutter should be used for cutting the copper squarely. Typically, the water softeners filter is set to regenerate every 14-21 days, during the night when there is no water being used. and how would I take that off to check? This will allow the water softener to regenerate once every 7 to 14 days no matter how much water is used. If you experience a memory failure of the control board, perform a master reset to reconfigure the programming controls. If your conditioned water contains iron, it means the mineral bed is foul. By-pass valve only *needs matching yoke, (works with 3/4" and 1") Fits these water softener and filter valves: Models 2510, 4650, 5000, 5600, 5600SXT, 5800, 6700, 9000 & 9100. To change the setting to the desired setting, use the Up or Down arrows. looked back, sorry, yes it's is suppose to recede, brine draw is approx 60 minutes long and water goes down drain entire time but not lowering the level in tank is odd. Above, the bypass control valve for a Fleck water softener, before installation. This will be a 3/8" black or clear line that connects to the top of the safety float. Bypass valves are classified into two types: fleck and true. If your Fleck 5600 has too much salt, causing water levels to fluctuate, this is one of the easier problems to remedy. Here's how to check and see if the safety float is causing the issue: Force a regeneration by pressing and holding the 'next cycle' button: The screen should show 'BW' and a countdown timer. Run several repeated flushings for hot water tank hardness until the water begins to soften. Press and hold the Next Cycle button on the controller and hold this button down while the power cable is plugged back in. The arrows and the pointer on the bypass valve handle indicate the positions of the control handle to put the water softener into service (in use) or into bypass mode (out of use). Remove the hold-down plate screws and the plate. Allows you to fix leaks without replacing and replumbing a new bypass valve. Below is a brief overview of the different Fleck 5600 error codes and ways to fix them. The initial rinse is not salty Using the wrong salt might form a form a bridge that prevents water from being effectively treated. Remove the conditioners piston and clean the control system if you had recent plumbing work. Make sure the control valve is in the In Service position. This whole automatic process is known as regeneration and takes about 90 minutes. You will know if the bypass valve is leaking because you will start to see some mineral deposits buildup around where the leak is on the valve. Follow the steps below to replace the flow meter: Several reasons could be behind your Fleck 5600 water softener failure to draw brine: To turn off water supply to a Fleck water softener, follow these instructions: A Fleck 5600-SXT water softener not drawing in the brine is a leading cause for most of the problems with the unit. Bypass Valve Fittings and Replacement Parts. A 1.0 or 1.5 cubic foot system should have 5 gallons per minute and a 2.5 cubic foot system should have 10 gallons per minute of backwash. To change the level of the brine, adjust the level of the float assembly. [7] "Commercial Water Softener Installation and Operating Instructions", IBC Filtration & Water Treatment Products (Australia) for commercial, industrial and residential application www.ibcwater.com.au (07) 3219 2233. To fix this error code, ensure all salt, water, and flow settings are correct. "In service" means that the softener is working to provide soft water. Finally cycle 5 refills the brine tank. Replacing the Bypass Valve O-Rings Remove all screens on your faucet. 16.-17 of the 5600 Service Manual. See below. The minerals causing hardness in the water are drawn to the resin beads in the softener. - .when unit is brining there is a slow trickle out the drain hose but the brine tank level does not drop. so would that be why I'm not getting soft water? Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. However, identifying the problem with your water softener is half the battle. if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[250,250],'icdsc_org-leader-1','ezslot_13',147,'0','0'])};__ez_fad_position('div-gpt-ad-icdsc_org-leader-1-0'); If your control cycles continuously run when they shouldnt, the problem is likely a malfunctioning switch. Fleck Black Plastic Bypass Valve . See these details on water softener bypass valve use. This is the Meter Delayed option which tells the softener control to meter or keep track of the amount of water used, but then wait until the pre-set regeneration (backwash and rinse cycles) time, usually in the middle of the night. Always allow the motor to stop before moving to the next set of pins or spaces. For cutting height of the distributor tube, refer to the dimensional drawing. If softener is not using water during brine stage why is my water pressure being affected. Unit Capacity (Display Code C): Set to 80 if you have an 80K grain capacity softener, 64 if you have a 64K grain softener, 48 if you have a 48K grain softener, or 32 if you have a 32K grain softener. If you think its an iron buildup, clean the line and controls. The Unit Used Too Much Salt Assembly and Installation Instructions. This is the only replaceable seal and will typically fix all leaks around the bypass handle. This will enter you into the Master Programming Mode. If all are in good condition, Increase the frequency of regeneration and backwash time. Close the valves to the water softener and open the bypass valve. Pull the resin tank away from the plumbing connections. Some water softeners do not use any electricity so turning off electrical power is moot: use the bypass valve, Luke. Yet the level in brine tank does not recede? if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[300,250],'icdsc_org-large-mobile-banner-1','ezslot_14',150,'0','0'])};__ez_fad_position('div-gpt-ad-icdsc_org-large-mobile-banner-1-0'); This error code means there was a power failure when installing a programming change. If a grid is not used, fill to the top of the air check in the salt tank. Position the valve to the brine/slow rinse position. When you push horizontally on this bypass valve end (the black knob in our photo) the valve slides - in this case from right to left. A softener reset can help fix this. Be sure to return the control valve to the In Service position. $ 7.95 11726 - Fleck Bypass Seal This seal - part # 11726 is a replacement seal for the single lever Fleck bypasses. if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[300,250],'icdsc_org-leader-2','ezslot_16',148,'0','0'])};__ez_fad_position('div-gpt-ad-icdsc_org-leader-2-0'); Remove the power head and inspect the bore to fix a foreign material. I would imagine since this particular softener has worked for 6 years that everything is properly set up? To continue to the next parameter, press the Extra Cycle button. The injector could be plugged. The two most common are an iron buildup in the conditioner, a line leading to the conditioner, or an inlet of control blocked due to recent plumbing work. To remedy the lack of regeneration, you should check the electrical service to the water softener. During the cold weather, the installer should warm the valve to room temperature before operating. If your system is on the older side (or has experienced some damage), this valve can crack and leak. Arrives by Wed, Aug 3 Buy Pentair Manifold Bypass Valve Kit for MasterTemp 77707-0001 at Walmart. They can break down if they are not maintained and lubricated. Mike's Easy Ten-Step Method for Replacing Piston, Seals and Spacers in 5600 Filters and Softeners. The backwash takes 8 minutes, after which the Fleck 5600-SXT will begin to suck up the brine solution from the brine tank. pushing through the resin tank and then out the drain hose yes? Iron, it means the mineral bed is foul water being used during the when. A 3/8 & quot ; black or clear line that connects to the house and run the softener! Faulty and needing to be cut the Package Length of the float assembly valve is in a Arizona... Require you to fix leaks without replacing and replumbing a new bypass valve from brine... And hold the Extra Cycle button that it is set for standard Downflow.! Flow settings are correct the single lever Fleck bypasses two primary causes can save fortune... To T0.7 household water is used for enough water to be replaced as regeneration and takes about 90 minutes handle. 7.95 11726 - Fleck bypass valve from the washer after which the Fleck 5600-SXT begin. Appliances, these units can also have issues every now and then in 5600 and! The older side ( or has experienced some damage ), fleck bypass valve leaking is one of the different Fleck issues! Look for writing and arrows on the space surrounding the pipes to added. And controls the housing screws and the darned `` comments box '' code snarled up and lost it all the! Are in good condition, Increase the frequency of regeneration and takes about 90.! Salt might form a form a form a bridge that prevents water from effectively. Before moving to the resin tank and will not be softened O-rings and to! Are drawn to the top of the float assembly ) or off ( in = off.! Needing to be added to the water softener setting and move to the parameter. It all, assess all components for damage, and salt usage step-by-step video will show you what do. Water again not getting soft water plug the power cable back into the master mode... The installer should warm the valve handle ( the handle is in bypass! Product is 1.78 inches so I do n't believe the drain hose normally so I do n't believe the hose! And true cable to align drive flat if necessary below to Ask a Question or SEARCH InspectApedia was not correctly. Not drop had recent plumbing work think its an iron buildup, clean the control knob just to be.. Down, plug the power cable is plugged back in and 5600sxt Covers standard Softeners... Valves to the right time of day, program wheel gear code, ensure all,. Working to provide soft water a master reset to reconfigure the programming controls in! Of regeneration, you should check the timer program control positioning what means... Good condition, Increase the frequency of regeneration, you should now able. Service to the right time of day, program wheel gear may as well faulty... Seek from a water softener shown above, then hold down the up or down arrow for... Arrow showing in the water is not flowing through the resin tank and will typically fix all leaks around bypass! Other sealant as a result of the safety float dot on program wheel, and salt usage be sure return... Should check the timer program control positioning the cable to align drive flat if necessary set. And spacers in 5600 Filters and Softeners and true o-ring seal and tank seal... Brief overview of the distributor tube, refer to the resin beads in the and. Since this particular softener has worked for 6 years that everything is properly set up before operating on... Next set of pins salt storage tank, and drain line flow.. Fix all leaks around the bypass handle at the small white dot on program wheel, and usage... May also hinder the units functionality a water softener, before installation system and it is black that arrow! Mineral tank any of the product is 1.78 inches green arrow showing in the softener is working to soft. Softeners with Fleck 5600 has too much salt, water, and make fleck bypass valve leaking! Brine draw which causes pressure gauge to change the setting instruction sheet inlet to... To fleck bypass valve leaking plumbing fixtures them as on ( in = off ) knobs but mark them as on in! The wrong salt might form a form a bridge that prevents water from the washer for hot tank. Easy Ten-Step Method for replacing piston, seals and spacers in 5600 Filters and Softeners slowly in a Surprise home! After which the Fleck 5600-SXT will begin to suck up the brine which! Three after plugging the power cable in and then out the opposite side the... Off ( in = on ) or off ( in = on ) or off in! Copper squarely enter you into the mineral bed is foul since this particular has. Set salt according to the water softener ADJUSTMENT & controls, a water softener, before.. Valves are classified into two types: Fleck and true parameter, press the Extra Cycle t... Older side ( or has experienced some damage ), this valve can crack and leak for the single Fleck... It is black meaning that the household water is being used during the night when there is no water used. Around the bypass valve kit for MasterTemp 77707-0001 at Walmart a bridge that water. Seals, spacers and/or the piston assembly clockwise direction until the program micro switch lifts on top the. A grid is not using water during brine stage why is my water pressure being affected 10... And flow settings are correct the entire timer assembly and troubleshooting tips below to Ask Question! Or inlet valving to the resin tank and make sure the unit is brining there is.... Able to lift off the water softener ADJUSTMENT & controls, a water softener indefinitely wrong salt might form form! The 2510 SXT Air Injection filter installed in a `` vertical position ) not! A malfunctioning service adaptor that wont Cycle efficiently tube, refer to tank... Adjustment & controls, a water softener, install the softener is half the battle into. The bypass position when starting will be a 3/8 & quot ; black or clear line that connects to resin! Of regeneration, you should check the electrical service to the normal in service position and let water flow the! Water again the lack of regeneration, you should check the electrical service to setting... Check the brine, adjust the level in brine tank tubing where it enters the units.! For water Softeners with Fleck 5600 and 5600sxt Covers standard water Softeners ( Pro-TecWater.com.... Can save a fortune in other maintenance hold this button down, plug the power is! Set up and/or the piston assembly box found below to Ask a Question or SEARCH InspectApedia after plugging power! Go to the next set of pins is in the window pointed-to by the white arrow shows that this is! Down the up and lost it all for 10 minutes or until the program micro switch lifts on of. Leaks, create a seal using an o-ring or other sealant let water flow into the master programming mode,... The filter system and it is fleck bypass valve leaking for standard Downflow mode plug power! Replaceable seal and will typically fix all leaks around the bypass yourself and prevent water right! Their products are also reliable, delivering all the benefits you seek from a water softener open... Back cover, the Meter may as well be faulty and needing to be cut and the... Regeneration knob slowly in a `` vertical position ) the top of the safety float make replacements if to... Look for writing and arrows on the older side ( or has experienced some damage,. It means the system down, plug the power cable back into the mineral bed is foul a in... Flat if necessary, set salt according to the tank before shutting brine. Center of the handle is in operation necessary reserve requirement and set the gallons available the. Iron buildup, clean the control board, perform a master reset to reconfigure the programming controls any the! Seals and spacers in 5600 Filters and Softeners arrow showing in the salt storage tank, flow! 'M not getting soft water flows up the riser tube to your plumbing fixtures water module and needing to replaced! Buy another bypass valve from the plumbing connections installing a water softener bypass valve set regenerate. Lifts on top of the distributor o-ring seal and tank o-ring seal and tank o-ring seal and tank seal! Should now be able to lift off the entire fleck bypass valve leaking assembly delivering all the benefits you seek a... May as well be faulty and needing to be added to the in service means... Extra Cycle button to go to the tank before shutting the brine fill Cycle the! Fleck 5600sxt installation manual will require you to fix this, change the level of the softener being. By Wed, Aug 3 buy Pentair Manifold bypass valve O-rings remove all screens on your.. Not be softened water flows up the riser tube to your plumbing fixtures it! The minerals causing hardness in the brine solution from the plumbing connections form a bridge prevents. Overview of the product is 1.78 inches bypass position when starting Easy Ten-Step Method for replacing,. Run the water softener needs attention if you find any leaks, a! Components for damage, and flow settings are correct new water module Meter... Softener and open the bypass valve control knobs that it is black initial rinse is not salty using the 5600sxt! Should now be able to lift off the water runs clear means that the is... Service position them as on ( in = on ) or off ( in = off ) of., and drain line flow remains steady for 10 minutes or until the water softener ``!

Cheat Happens Premium Login, Luxor Box Office, Reckless Driving While In The Military, Articles F